Fast Absolute 3D CGO-Based Electrical Impedance Tomography on Experimental Tank Data

01/04/2023
by   S. J. Hamilton, et al.
0

Objective: To present the first 3D CGO-based absolute EIT reconstructions from experimental tank data. Approach: CGO-based methods for absolute EIT imaging are compared to traditional TV regularized non-linear least squares reconstruction methods. Additional robustness testing is performed by considering incorrect modeling of domain shape. Main Results: The CGO-based methods are fast, and show strong robustness to incorrect domain modeling comparable to classic difference EIT imaging and fewer boundary artefacts than the TV regularized non-linear least squares reference reconstructions. Significance: This work is the first to demonstrate fully 3D CGO-based absolute EIT reconstruction on experimental data and also compares to TV-regularized absolute reconstruction. The speed (1-5 seconds) and quality of the reconstructions is encouraging for future work in absolute EIT.

READ FULL TEXT

Please sign up or login with your details

Forgot password? Click here to reset

Sign in with Google

×

Use your Google Account to sign in to DeepAI

×

Consider DeepAI Pro