Live-wire 3D medical images segmentation

06/14/2013
by   Ognjen Arandjelovic, et al.
0

This report describes the design, implementation, evaluation and original enhancements to the Live-Wire method for 2D and 3D image segmentation. Live-Wire 2D employs a semi-automatic paradigm; the user is asked to select a few boundary points of the object to segment, to steer the process in the right direction, while the result is displayed in real time. In our implementation segmentation is extended to three dimensions by performing this process on a slice-by-slice basis. User's time and involvement is further reduced by allowing him to specify object contours in planes orthogonal to the slices. If these planes are chosen strategically, Live-Wire 3D can perform 2D segmentation in the plane of each slice automatically. This report also proposes two improvements to the original method, path heating and a new graph edge feature function based on variance of path properties along the boundary. We show that these improvements lead up to a 33 improved delineation in presence of strong interfering edges.

READ FULL TEXT

Please sign up or login with your details

Forgot password? Click here to reset